Abstract:
Ongoing clinical trials designed to explore the use of extracranial stereotactic radiosurgery (ESR) for different tumour sites use large doses per fraction (15, 20, 30 Gy or even larger). The question of whether the linear-quadratic (LQ) model is appropriate to describe radiation response for such large fraction doses has been raised and has not been answered definitively. It has been proposed that mechanism-based models, such as the lethal-potentially lethal (LPL) model, could be more appropriate for such large fraction/acute doses. However, such models are not well characterized with clinical data and they are generally not easy to use. The purpose of this work is to modify the LQ model to more accurately describe radiation response for high fraction/acute doses. A new parameter is introduced in the modified LQ (MLQ) model. The new parameter introduced is characterized based both on in vitro cell survival data of several human tumour cell lines and in vivo animal iso-effect curves. The MLQ model produces a better fit to the iso-effect data than the LQ model. For a high single dose irradiation, the prediction of the MLQ is consistent with that from the LPL model. Unlike the LPL model, the MLQ model retains the simplicity of the LQ model and uses the well-characterized alpha and beta parameters. This work indicates that the standard LQ model can lead to erroneous results when used to calculate iso-effects with large fraction doses, such as those used for ESR. We present a solution to this problem.
More Related Videos
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Pharmacodynamic Models: Linear Concentration–Effect Model
Nonlinear Pharmacokinetics: Overview
Nonlinearity can arise due to the saturation of plasma protein-binding or...
Dosage Regimens: Partial Pharmacokinetic Parameters
Pharmacodynamic Models: Additive and Proportional Drug Effect Model
Model Approaches for Pharmacokinetic Data: Distributed Parameter Models
The distributed parameter models are specifically designed to account for variations and differences in some drug classes. This model is particularly useful for assessing regional concentrations of anticancer or...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations