Radionuclide imaging of miniaturized chemical analysis systems
Martin Lavén1, Susanne Wallenborg, Irina Velikyan
1Department of Analytical Chemistry, Institute of Chemistry, Uppsala University, Box 599, SE-751 24 Uppsala, Sweden.
Abstract:
We propose radionuclide imaging as a valuable tool for the study of molecular interactions in miniaturized systems for chemical analysis. Sensitive and quantitative imaging can be performed with compounds labeled with short-lived positron-emitting radionuclides, such as (11)C and (68)Ga, within selected parts of the system. Radionuclide imaging is not restricted to transparent materials since the relatively energetic positrons can penetrate high optical density materials. Experimentally, a radiotracer is introduced into the object of study, which is subsequently placed on a phosphor storage plate. After exposure, the plate is scanned with a laser and a digital, quantitative image can be reconstituted. To demonstrate the concept, three types of microstructures suited for integration in chemical analysis systems were imaged with (11)C- and (68)Ga-labeled tracers. The influence of factors such as geometry of the object and type of radionuclide on resolution and sensitivity was investigated. The resolution ranged from 0.9 to 2.7 mm (fwhm). Measuring low amounts of radioactivity in the three structures, 2-20 Bq could be detected, which corresponded to 2.3-500 amol or 2.4-110 pM tracer. The imaging approach was applied to study analyte concentration and sample dilution effects on the performance of a capillary extraction column integrated in an automated LC-ESI-MS system. The utility of the technique was further illustrated by imaging of microchannels in a zeonor plastic compact disk and in a poly(dimethylsiloxane) material for the study of nonspecific peptide adsorption.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...