Related Experiment Video
Updated: Aug 20, 2026

Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
Mitigation of a radon-rich Belgian dwelling using active subslab depressurization
Johan Paridaens1, Louis de Saint-Georges, Hans Vanmarcke
1Belgian Nuclear Research Centre, SCK-CEN, Boeretang 200, B-2400 Mol, Belgium. jparidae@sckcen.be
Abstract:
In a radon prone area in Belgium, a dwelling with high indoor radon concentrations was identified through a passive measurement. Next, a continuous, active radon monitoring device was installed for one month. A 20-a retrospective radon assessment was also performed. The house was subsequently mitigated through active subslab depressurization with a radial fan. Afterwards the dwelling was actively monitored for several more months to observe the effects of the mitigation and to study the effect of reducing the fan power. Dose evaluations were made to evaluate the health benefit of the mitigation. It was seen that the results of the three measuring techniques before mitigation all yielded between 1700 and 2000 Bq/m3. Clear diurnal radon variations showed up only after mitigation. After mitigation, the average radon concentration fell to less than 200 Bq/m3. The yearly average dose was reduced from potentially 45 mSv/y to less than 4.5 mSv/y through mitigation. Reducing fan power to 50% did not clearly influence the amount of radon entering into the dwelling.
Related Concept Videos
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction facilitates the...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh.