Related Experiment Video
Updated: Jul 9, 2026

A Protocol for Comprehensive Assessment of Bulbar Dysfunction in Amyotrophic Lateral Sclerosis (ALS)
Published on: February 21, 2011
Reliability and applicability of aerodynamic measures in dysphonia assessment
Edwin M L Yiu1, Yuet-Ming Yuen, Tara Whitehill
1Voice Research Laboratory, The University of Hong Kong. eyiu@hku.hk
Abstract:
Aerodynamic measures are frequently used to analyse and document pathological voices. Some normative data are available for speakers from the English-speaking population. However, no data are available yet for Chinese speakers despite the fact that they are one of the largest populations in the world. The high variability of aerodynamic measures between and within subjects raises the issue of reliability and usefulness of this procedure in discriminating between normal and pathological voices. This study aimed to investigate the use of mean airflow rate and sub-glottal pressure in predicting normal and pathological voices. It also aimed to determine whether a higher number of repeated airflow measures would provide a better representation of the normative data in distinguishing normal from abnormal voices. The study provided a small set of preliminary normative data for Chinese speakers. Aerodynamic measures were collected from 56 Cantonese female adults using a Kay Elemetrics Aerophone II. The results showed that the accuracy in predicting a voice to be dysphonic or normal using aerodynamic measures was as high as 91.1%. The accuracy was found to improve when the number of measurements for each aerodynamic parameter was increased from three to five. The overlapping of data between the dysphonic and non-dysphonic groups, however, suggests that the aerodynamic measures should be used as an adjunct to assessment of voice disorders rather than as a diagnostic tool alone.
Related Concept Videos
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Physical Assessment of the Respiratory Tract II: Palpation
Thoracic Palpation
Thoracic palpation detects tenderness, masses, lesions, respiratory excursions, and vocal fremitus. The nurse assesses...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Physical Assessment of the Respiratory Tract IV: Auscultation
Breath Sounds
Breath sounds are categorized into vesicular, bronchovesicular, and bronchial.
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:

