Related Experiment Video
Updated: Aug 20, 2026

Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Further characterization of the supine empty stress test for predicting low valsalva leak point pressures
Andrew J Walter1, Jennifer A Thornton, Andrew C Steele
1Division of Urogynecology at Kaiser Permanente, Sacramento, CA, USA. Andrew.J.Walter@kp.org
Abstract:
The aim of this study is to determine if the diagnostic accuracy of the supine empty stress test (SEST) differs depending on the volume of residual urine. We performed a review of all patients who were diagnosed with stress urinary incontinence (SUI) via multi-channel urodynamics including valsalva leak point determinations (VLPP). A SEST was performed and the residual urine recorded via catheterization. The test-specific indices of the SEST for the prediction of low VLPP (defined as <60 cm H(2)0) were determined for varying residual volumes. Ninety-nine patients were included. Regardless of residual volume, low sensitivities, specificities and positive predictive values were demonstrated. Sensitivity and positive predictive values were further reduced and negative predictive values were improved slightly with higher residual volume. The highest negative predictive value was 89% at a residual volume of greater than 10 mL. Residual urine volume has minimal impact on the utility of the SEST.
Related Concept Videos
Urodynamic Studies: Uroflowmetry
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies