Related Experiment Video
Updated: Aug 16, 2026

10:40
High Resolution Phonon-assisted Quasi-resonance Fluorescence Spectroscopy
Published on: June 28, 2016
[Theoretical and experimental vibrational spectroscopy study of K3Ln(PO4)2 phosphates]
L Benarafa1, L Rghioui, R Nejjar
1Laboratoire de Spectroscopie Infrarouge, Département de Chimie, Faculté des Sciences, Rabat, Morocco.
Spectrochimica Acta. Part A, Molecular and Biomolecular Spectroscopy
|December 8, 2004
Abstract:
The monoclinic phosphates with K3Ln(PO4)2 (Ln=rare earth) formula were synthesized. Their infrared and Raman spectra have been reported and analysed. The results of a force field calculation for K3Nd(PO4)2 are presented.
Related Concept Videos
Predicting Molecular Geometry
VSEPR Theory for Determination of Electron Pair Geometries
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
A covalently bonded heteronuclear diatomic molecule can be modeled as two vibrating masses connected by a spring. The vibrational frequency of the bond can be expressed using an equation derived from Hooke's law, which describes how the force applied to stretch or compress a spring is proportional to the displacement of the spring. In this case, the atoms behave like masses, and the bond acts like a spring.
According to Hooke's law, the vibrational frequency is directly proportional to the...
According to Hooke's law, the vibrational frequency is directly proportional to the...
Variables Affecting Phosphorescence and Fluorescence
Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
Photoluminescence: Applications
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Fluorescence and Phosphorescence: Instrumentation
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Flame Photometry: Lab
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...

