Sources of measurement error in an ECG examination: implications for performance-based assessments
David J Solomon1, Gary Ferenchick
1Michigan State University, E. Lansing, MI 48823, USA. dsolmon@msu.edu
Objective:
To assess the sources of measurement error in an electrocardiogram (ECG) interpretation examination given in a third-year internal medicine clerkship.
Design:
Three successive generalizability studies were conducted. (1) Multiple faculty rated student responses to a previously administered exam. (2) The rating criteria were revised and study 1 was repeated. (3) The examination was converted into an extended matching format including multiple cases with the same underlying cardiac problem.
Results:
The discrepancies among raters (main effects and interactions) were dwarfed by the error associated with case specificity. The largest source of the differences among raters was in rating student errors of commission rather than student errors of omission. Revisions in the rating criteria may have helped increase inter-rater reliability slightly however, due to case specificity, it had little impact on the overall reliability of the exam. The third study indicated the majority of the variability in student performance across cases was in performance across cases within the same type of cardiac problem rather than between different types of cardiac problems.
Conclusions:
Case specificity was the overwhelming source of measurement error. The variation among cases came mainly from discrepancies in performance between examples of the same cardiac problem rather than from differences in performance across different types of cardiac problems. This suggests it is necessary to include a large number of cases even if the goal is to assess performance on only a few types of cardiac problems.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Random and Systematic Errors
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...