Sensitive method for the determination of roxarsone using solid-phase microextraction with multi-detector gas
Aaron R Roerdink1, Joseph H Aldstadt
1Department of Chemistry, University of Wisconsin-Milwaukee, Milwaukee, WI 53211-3029, USA.
Abstract:
We describe the development, optimization, and application of a novel method for the unequivocal identification and quantification of roxarsone (3-nitro-4-hydroxyphenylarsonic acid, 3-NHPAA) at low microg L(-1) levels. The method is based on capillary gas-liquid chromatography with parallel quadrupole ion-trap mass spectrometric (QIT-MS) and pulsed flame photometric detection (PFPD). The sensitive method couples the arsenic specificity of PFPD with the high selectivity of molecular MS for the determination of roxarsone, dimethylarsenic acid (DMAA), and monomethylarsonic acid (MMAA) in complex matrices. Analytes were derivatized based on the approach we previously reported [B. Szostek, J.H. Aldstadt, J. Chromatogr. A 807 (1998) 253 and D.R. Killelea, J.H. Aldstadt, J. Chromatogr. A 918 (2001) 169] for the reaction of organoarsenicals with 1,3-propanedithiol (PDT). The cyclic dithiaarsenolines formed were extracted from the sample matrix in the liquid phase by solid-phase microextraction (SPME). The optimized SPME conditions employed a 65 microm polydimethlysiloxane-divinylbenzene (PDMS-DVB) fiber, extraction temperature of 70 degrees C and fiber equilibration time of 15.0 min. The mass spectrum of the dithiaarsenoline of roxarsone showed a base peak that corresponded to the predicted structure at m/z 319 and the tell-tale peak of an arsenic compound derivatized with PDT at m/z 181. Further peaks at m/z 149 and 228 were observed and found to be unique to roxarsone, formed by an interesting internal rearrangement of the ONOH functionality. A linear calibration model was prepared for roxarsone over an environmentally relevant range (0.0-100 microg L(-1)) and a detection limit of 2.69 microg L(-1) (3sigma) was observed. The method was applied to several fortified environmental surface water samples (50 microg L(-1)) where the average recovery for roxarsone was 103+/-10.9%.
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...