High-contrast microscopy of semiconductor and metal sites in integrated circuits by detection of optical feedback

Vernon Julius Cemine1, Bernardino Buenaobra, Carlo Mar Blanca

  • 1National Institute of Physics, University of the Philippines, Diliman, Quezon City 1101, Philippines.

Optics Letters
|December 9, 2004
PubMed

Related Concept Videos

Metal-Semiconductor Junctions01:24

Metal-Semiconductor Junctions

The contact of metal and semiconductor can lead to the formation of a junction with either Schottky or Ohmic behavior.
Schottky Barriers
Schottky barriers arise when a metal with a work function (Φm) contacts a semiconductor with a different work function (Φs). Initially, electrons transfer until the Fermi levels of the metal and semiconductor align at equilibrium. For instance, if Φm > Φs, the semiconductor Fermi level is higher than the metal's before contact. The semiconductor's...
Biasing of Metal-Semiconductor Junctions01:27

Biasing of Metal-Semiconductor Junctions

Biasing metal-semiconductor junctions involves applying a voltage across the junction. Specifically, the metal is connected to a voltage source, while the semiconductor is grounded. This technique is essential for controlling the direction and magnitude of current flow in electronic devices, including diodes, transistors, and photovoltaic cells.
In Schottky junctions, where the semiconductor is n-type, applying a positive voltage to the metal relative to the semiconductor reduces its Fermi...
MOSFET: Enhancement Mode01:22

MOSFET: Enhancement Mode

Enhancement-mode MOSFETs are pivotal components in electronics, distinguished by their capacity to act as highly efficient switches. They are part of the larger family of metal-oxide Semiconductor Field-Effect Transistors (MOSFETs). They are available in two types: p-channel and n-channel, each tailored to specific polarity operations.
In their basic form, enhancement-mode MOSFETs are typically non-conductive when the gate-source voltage (Vgs) is zero. This default 'off' state means no current...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...