Effect of mouthpiece washing on aerosol performance of CFC-free Ventolin
Nora Y K Chew1, Helen K Reddel, Sinthia Z Bosnic-Anticevich
1Faculty of Pharmacy, University of Sydney, Australia.
Abstract:
The prescribing information for chlorofluorocarbon (CFC)-free salbutamol metered-dose inhalers carries a strongly-worded instruction to wash the mouthpiece weekly, but patients rarely carry this out. This study investigated the effect of washing/not washing the mouthpiece on CFC-free Ventolin aerosol performance. Twelve CFC-free Ventolin inhalers were actuated two puffs four times/day, and assessed by unit dose sampler and cascade impactor on Days 1, 7, 8, 14, 15, 21, and 22 ("throughlife," i.e., over the entire content of the inhaler). The mouthpieces of six inhalers were washed after the last actuation on Days 7, 14, and 21. A single priming maneuver, as recommended by the manufacturer, was sufficient for fine particle mass. There were no significant through-life differences in delivered dose between washed and unwashed inhalers. Without washing, fine particle mass fell from 47 microg to 33 microg (Friedman p=0.002). Fine particle mass increased significantly after washing (median change + 11.2 microg, p=0.019 cf. unwashed). Large particle mass showed no significant through-life trend for washed or unwashed inhalers, but was significantly reduced after washing (p=0.04 cf. unwashed). This study shows a progressive through-life reduction in fine particle mass from CFC-free Ventolin inhalers, which is prevented by weekly mouthpiece washing. However, in view of the steep bronchodilator dose-response curve for salbutamol, further studies are needed to determine whether such device care is clinically necessary.
Related Concept Videos
Inhaled Medications
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Upper Respiratory Drugs: Antitussives, Expectorants, and Mucolytics
Antitussives include codeine, dextromethorphan (Robitussin), and benzonatate (Tessalon). Codeine and dextromethorphan exert their effects centrally by suppressing the cough reflex center in the medulla. Benzonatate operates peripherally within the respiratory tract by anesthetizing...
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils, connected...