Related Experiment Video
Updated: Aug 20, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
Short-wavelength automated perimetry can predict glaucomatous standard visual field loss by ten years
Arthur J Sit1, Felipe A Medeiros, Robert N Weinreb
1Hamilton Glaucoma Center, Department of Ophthalmology, University of California, San Diego, La Jolla, CA 92093-0946, USA.
Abstract:
Examination of visual fields using standard achromatic automated perimetry (SAP) is essential for glaucoma management. However, as many as 35-50% of retinal ganglion cells can be lost before a visual field defect is detected. Previous studies have indicated that examination of the short-wavelength (blue) sensitive color system may be able to detect early functional loss in glaucoma. Moreover, it has been reported to detect glaucomatous visual field loss as many as 5 years earlier than SAP. We describe the case of a patient who demonstrated visual field defects on short-wavelength automated perimetry (SWAP) ten years prior to developing visual field defects in SAP.