To report the systematic comparison of magnetic resonance imaging (MRI) with contrast-enhanced computed tomography (CT) for evaluating 8 different aortic stent-graft models.
Methods:
MR angiography (MRA) was performed using a 1.5-T whole body system within 2 days of a CT examination (4 detector row scanner) on 8 patients with one of these stent-graft models: AneuRx, Endofit, PowerLink, Excluder, LifePath, Talent, Vanguard, or Zenith. Using a 4-point scale (maximum score 112 points), 4 independent readers (1 vascular surgeon and 3 radiologists) rated the impact of stent-related artifacts on the diagnostic quality of each imaging method for 28 parameters: length, diameter, collateral aortic side branches, stent-graft prostheses, and contrast. Each examiner also scored his personal diagnostic confidence with each stent-graft model.
Results:
The scores for diagnostic confidence in the CT imaging were 4 points for each stent-graft, with the exception of the LifePath (3 points). The diagnostic confidence in the MR images was mainly poor, with a median score of only 1; however, 3 stent-grafts (AneuRx, Excluder, and Vanguard) received > or =3 points. The total scores for comparative assessment were significantly different (p<0.05) between CT imaging (111.5) and MR (58.5). CT studies of all stent-grafts received >101 points, while only 3 devices acquired >80 points (AneuRx, Excluder, and Vanguard). Bland-Altman analysis showed that the reliability of the 4 readers was higher using the CT method. The total assessment scores of the stent-graft systems were related only on the different imaging methods (p<0.0001) and not to the different readers (p=0.983).
Conclusions:
CT and MRI are fast, reliable means of providing all relevant information for stent-graft surveillance. Of 8 different stent-graft models, only 3 could be adequately assessed by MRA. Therefore, the potential advantages of the MR technique (e.g., use of minimally nephrotoxic contrast media, lack of ionizing radiation) are available only to a small proportion of patients.
More Related Videos
11:16In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Magnetic Resonance Imaging