Related Experiment Video
Updated: Aug 20, 2026

Estimation of Urinary Nanocrystals in Humans using Calcium Fluorophore Labeling and Nanoparticle Tracking Analysis
Published on: February 9, 2021
Flow injection spectrophotometric determination of Al in hemodialysis solutions
Jairo Lisboa Rodrigues1, Cristiana Schmidt de Magalhães, Pedro Orival Luccas
1Departamento de Ciências Exatas, Escola de Farmácia e Odontologia de Alfenas-Centro Universitário Federal, Cep 37130-000 Alfenas, MG, Brazil.
Abstract:
A flow analysis (FA) system with spectrophotometric detection for Al determination in hemodialysis solutions was developed. The method was based on the reaction of Al with eriochrome cyanine R (ECR). The complex formed associated with cetyltrimethylammonium bromide (CTAB)--a cationic surfactant, which showed enough sensitivity to execute the direct analyte determination. All interferences were eliminated with the matrix matching calibration. The system presented the following analytic parameters: sensitivity (m) of 8.10 x 10(-4)L microg(-1), limit of detection (LOD) of 3.24 microg L(-1) (3sigma), linear correlation coefficient of 0.9966 and linear range response from 10.8 to 650 microg L(-1). The accuracy of the proposed method was checked by comparison with electrothermal atomic absorption spectrometry (ET-AAS) method. There were no differences among the results obtained from both methods, at a confidence level of 95% (paired t-test). Recovery tests were also made, values obtained were from 90.4 to 109 of recovery for Al-spiked samples.
More Related Videos
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
09:24Application and Methodology of the Non-destructive 19F Time-domain NMR Technique to Measure the Content in Fluorine-containing Drug Products
Published on: August 22, 2017
Related Concept Videos
EDTA: Indirect and Alkalimetric Titration
Protein-Drug Binding: Determination Methods
Indirect methods involve isolating the bound drug from its free form in biological samples such as blood, serum, or plasma. These techniques aim to measure the percentage of drugs bound to proteins. Equilibrium dialysis is a commonly used method where the free drug concentration at equilibrium is measured by separating the bound...
Drug Dosing in Renal Diseases: Measurement of Glomerular Filtration Rate
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Drug Concentrations: Measurements
Plasma —...
Estimation of k and VD of Aminoglycosides