Low-Cost, Volume-Controlled Dipstick Urinalysis for Home-Testing
Published on: May 8, 2021
Urine collection pads: are samples reliable for urine biochemistry and microscopy?
Peter I Macfarlane1, Robert Ellis, Christopher Hughes
1Department of Child Health, Rotherham General Hospital, Rotherham S60 2UD, UK. peter.macfarlane@rothgen.nhs.uk
Abstract:
The aim of the study was to validate the reliability of samples obtained with urine collection pads (UCP) for selected laboratory biochemical analyses, urine cell microscopy, and bedside semi-quantitative stick urinalysis. A series of laboratory experiments was performed to test agreement between urine concentrations, or results, before and after passage through a UCP (incubated for 37 degrees C for 15 min). The following urinalyses were performed: electrolytes, calcium, phosphate, urate, osmolality, pH, protein, catecholamines, toxicology for drugs of abuse, stick urinalysis for glucose, ketones, protein, blood, leucocytes and nitrites, and microscopy for red and white cells. Close agreement was shown for all laboratory analyses except proteinuria, which was underestimated by, on average, 10% after UCP passage. However, stick urinalysis for proteinuria remains sufficiently reliable for clinical use. UCP substantially retain or destroy red and white cells, but stick urinalysis for blood and leucocyte esterase remains reliable. In conclusion, urine samples derived from UCP show good agreement across a clinically relevant range for the biochemical analyses undertaken in this study. Microscopy of UCP samples is unreliable for cellular material but semi-quantitative stick urinalysis for red and white cells is a satisfactory alternative.
Related Concept Videos
Urine Studies I: Urinalysis
Urine Studies II: Urine Culture and Sensitivity Test
Urinary Tract Infection III: Diagnostic Studies and Interprofessional Care
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Microbiota of the Urogenital Tract
Urine: Physical and Chemical Properties
The concentration of these solutes varies, with urea being the most abundant nitrogenous waste product. Other solutes include sodium, chloride, potassium, phosphate,...