Related Experiment Video
Updated: Jul 31, 2026

Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Cardiac ejection fraction: phantom study comparing cine MR imaging, radionuclide blood pool imaging, and
J F Debatin1, S N Nadel, J F Paolini
1Department of Radiology, Duke University Medical Center, Durham, NC 27710.
Abstract:
The accuracy and reproducibility of cardiac ejection fraction (EF) measurements based on cine magnetic resonance (MR) imaging, radionuclide multigated acquisition (MUGA) blood pool imaging, and angiographic ventriculography were evaluated by comparing them with a volumetrically determined standard. A biventricular, compliant, fluid-filled heart phantom was developed to mimic normal cardiac anatomy and physiology. Ventricular EFs were measured with cine MR imaging by summation of nine contiguous 10-mm-thick sections in short and long axis, with single-plane ventriculography, and with MUGA. Three measurements were performed with each modality for each of three EFs. Ventriculography was least accurate, with average relative errors ranging from 7.9% for the largest EF to 60.1% for the smallest. Cine MR was most accurate, with average relative errors ranging from 4.4% to 8.5%. MUGA EF measurements showed good correlation, with average relative errors ranging from 7.1% to 22.4%. Comparison of the error variances for the three modalities with the F test revealed that MR and MUGA EF measurements were significantly more accurate than those based on ventriculography (P less than .01). No significant difference was demonstrated between the accuracy of short- and long-axis cine MR acquisitions.
More Related Videos
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT

