Related Experiment Video
Updated: Aug 20, 2026

Curtain Flow Column: Optimization of Efficiency and Sensitivity
Published on: June 12, 2016
Rationalisation of unusual changes in efficiency and retention with temperature shown for bases in reversed-phase
Stephan M C Buckenmaier1, David V McCalley, Melvin R Euerby
1Centre for Research in Biomedicine, University of the West of England, Frenchay, Bristol BS16 1QY UK.
Abstract:
Despite the possibility of poorer peak shapes, analysis of pharmaceuticals and other bases using reversed-phase high-performance liquid chromatography (RP-HPLC) at intermediate pH gives useful increases in retention, selectivity and column loading capacity compared with low pH. Retention times of some bases showed anomalous increases with column temperature. Peak shapes for bases improved significantly at elevated temperature (up to 70 degrees C), with the weakest bases studied (pKa approximately 8) giving greater improvement than the strongest bases (pKa approximately 10). In contrast, quaternary ammonium compounds showed reduced retention with increasing column temperature (normal behaviour) and only modest improvements in peak shape. Considering these results, and pKa measurements of the bases made using capillary electrophoresis, it appears that increases in retention and improvement in efficiency may be influenced significantly by reduction in the pKa of bases with temperature, leading to reduction in protonation. It is less likely that efficiency improvements are due to the speeding up of the kinetics of silanol ion exchange, at least in the temperature range studied here.
More Related Videos
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Chromatographic Methods: Terminology
Ion-Exchange Chromatography