Objective:
To analyze the efficacy of periodically changing ventilator circuits for decreasing the rate of ventilator-associated pneumonia when a heat and moisture exchanger (HME) is used for humidification. The Centers for Disease Control and Prevention recommended not changing the circuits periodically.
Design:
Randomized, controlled trial conducted between April 2001 and August 2002.
Setting:
A 24-bed, medical-surgical intensive care unit in a 650-bed, tertiary-care hospital.
Patients:
All patients requiring mechanical ventilation during more than 72 hours from April 2001 to August 2002.
Interventions:
Patients were randomized into two groups: (1) ventilation with change of ventilator circuits every 48 hours and (2) ventilation with no change of circuits. Throat swabs were taken on admission and twice weekly until discharge to classify pneumonia as endogenous or exogenous.
Results:
Three hundred four patients (143 from group 1 and 161 from group 2) with similar characteristics (age, gender, Acute Physiology and Chronic Health Evaluation II score, diagnostic group, and mortality) were analyzed. There was no significant difference in the rate of pneumonia between the groups (23.1% vs 23.0% and 15.5 vs 14.8 per 1,000 ventilator-days). There was no significant difference in the incidence of exogenous pneumonia per 1,000 days of mechanical ventilation (1.71 vs 1.25). There was no difference in the distribution of microorganisms causing pneumonia.
Conclusions:
Circuit change using an HME for humidification does not decrease pneumonia and represents an unnecessary cost.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)
Mechanical Ventilation I: Indication and Settings
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...