Related Experiment Videos
Effect of adrenaline on plasma concentrations of fentanyl during epidural anaesthesia for caesarean section
R Desprats1, M Giroux, J C Dumas
1INSERN CJF 9406 Toulouse, France; Department of Anaesthetics, La Grave Hospital, Toulouse, France.
The present study was designed to assess the effect of adrenaline on the plasma concentrations of fentanyl in mothers and umbilical vessels after epidural administration for caesarean section. Thirty patients undergoing elective caesarean section were allocated randomly into two groups. Group 1 (n = 16) received 100 microg fentanyl, 10 ml of 0.5% bupivacaine and 10 ml 2% lidocaine, while group II (n = 14) received 100 microg fentanyl, 10 ml of 0.5% bupivacaine with adrenaline 1:200 000, and 10 ml of 2% lidocaine with adrenaline 1:80 000. Blood samples were obtained from the maternal antecubital vein (MV) at various times up to 6 hours after epidural injection, and from umbilical vein (UV) and arteries (UA) at birth for determination of plasma fentanyl by radioimmunoassay. Fentanyl Cmax and Tmax in MV did not differ significantly between the two groups. In umbilical vessels, plasma fentanyl concentrations were comparable in the two groups: (0.12 +/- 0.08 ng ml(-1) and 0.13 +/- 0.08 ng ml(-1) in UV and 0.08 +/- 0.07 ng ml(-1) and 0.06 +/- 0.05 ng ml(1) in UA of groups I and II respectively). The maximum plasma concentration in UV was 0.24 ng ml(-1) in group I and 0.25 ng ml(-1) in group II. There was no significant correlation between umbilical vessel (vein or artery):MV ratio and dose to delivery interval and no difference between the two groups in Apgar score or umbilical cord pH.
The present study was designed to assess the effect of adrenaline on the plasma concentrations of fentanyl in mothers and umbilical vessels after epidural administration for caesarean section. Thirty patients undergoing elective caesarean section were allocated randomly into two groups. Group 1 (n = 16) received 100 microg fentanyl, 10 ml of 0.5% bupivacaine and 10 ml 2% lidocaine, while group II (n = 14) received 100 microg fentanyl, 10 ml of 0.5% bupivacaine with adrenaline 1:200 000, and 10 ml of 2% lidocaine with adrenaline 1:80 000. Blood samples were obtained from the maternal antecubital vein (MV) at various times up to 6 hours after epidural injection, and from umbilical vein (UV) and arteries (UA) at birth for determination of plasma fentanyl by radioimmunoassay. Fentanyl Cmax and Tmax in MV did not differ significantly between the two groups. In umbilical vessels, plasma fentanyl concentrations were comparable in the two groups: (0.12 +/- 0.08 ng ml(-1) and 0.13 +/- 0.08 ng ml(-1) in UV and 0.08 +/- 0.07 ng ml(-1) and 0.06 +/- 0.05 ng ml(1) in UA of groups I and II respectively). The maximum plasma concentration in UV was 0.24 ng ml(-1) in group I and 0.25 ng ml(-1) in group II. There was no significant correlation between umbilical vessel (vein or artery):MV ratio and dose to delivery interval and no difference between the two groups in Apgar score or umbilical cord pH.
Related Concept Videos
Local Anesthetics: Clinical Application as Epidural Anesthesia
Since epidural anesthetics can be infused through an epidural catheter, all types of drugs, including short-acting ones, can be administered. Chloroprocaine and lidocaine are examples of short and long-duration anesthetics, respectively. Bupivacaine...
Parenteral Anesthetics: Overview
Local Anesthetics: Pharmacokinetics
Local Anesthetics: Clinical Application as Spinal Anesthesia
Adrenergic Agonists: Therapeutic Uses
Emergency and Intensive Care Unit (ICU) applications: Pressor agents increase blood pressure, heart rate, and contractility in shock and organ failure situations. Dopamine can induce vasodilation and stimulate adrenoceptors. Endogenous catecholamines are effective in treating cardiogenic shock. α2-agonists like clonidine can reverse anesthesia-induced hypertension.
Allergies and anaphylaxis:...
Cardiopulmonary Resuscitation IV: Pharmacological Management