Measurement of Dynamic Scapular Kinematics Using an Acromion Marker Cluster to Minimize Skin Movement Artifact
Published on: February 10, 2015
A novel technique for recording from the serratus anterior
Michael J Depalma1, William S Pease, Ernest W Johnson
1Department of Physical Medicine and Rehabilitation, Ohio State University, Columbus, OH 43120, USA.
Objective:
To design an electrodiagnostic technique by which to accurately record the serratus anterior compound muscle action potential (CMAP).
Design:
Observational study.
Setting:
Academic electromyography laboratory.
Participants:
Fifteen healthy volunteers.
Interventions:
The long thoracic nerve was stimulated by using a standard bipolar surface electrode in the axilla, just anterior to the midaxillary line. The serratus anterior CMAP was recorded by using a self-adhesive, 8.0 x 0.5 cm, ring electrode as the E1 placed across the serratus anterior interdigitations starting at the nipple level. A self-adhesive, motor (1 x 1 cm) electrode was used as E2 and placed over the seventh rib. A standard self-adhesive ground electrode was placed over the inferior region of the latissimus dorsi.
Main Outcome Measures:
Distal motor latency (DML), and CMAP amplitude and duration.
Results:
After removing 2 outliers, the results are reported as the mean +/- 1.96 standard deviations. Right long thoracic DML was 2.2+/-1.0ms and the left was 2.3+/-0.9ms, with a side-to-side mean difference of 0.3+/-0.4ms. The right serratus CMAP amplitude was 3.8+/-3.9mV and the left was 3.9+/-3.7mV, with a side-to-side mean difference of 0.6+/-1.2mV. Statistical analysis did not reveal a significant side-to-side difference for DML or CMAP amplitude. Both sides were combined to form a single set of trials for DML and CMAP amplitude. The mean DML became 2.2+/-0.7ms, and the CMAP amplitude was 3.5+/-1.9mV. The CMAP duration was 14.5+/-4.3ms on the right and 14.5+/-4.1ms on the left. A significant, positive correlation existed between height and DML ( P <.02). The 95% confidence intervals for DML and CMAP amplitudes were 2.1 to 2.5ms and 1.5 to 3.1mV, respectively.
Conclusions:
Our latency, side-to-side comparisons and amplitude data were consistent with other motor nerve conduction findings in the literature. Stimulating the long thoracic nerve in the axilla will provide a reliable technique to aid in the diagnosis and treatment of long thoracic neuropathy.