Comparison of Polar 810s and an ambulatory ECG system for RR interval measurement during progressive exercise
M Kingsley1, M J Lewis, R E Marson
1Department of Sports Science, University of Wales, Swansea, UK. M.I.C.Kinglsey@Swansea.ac.uk
Abstract:
Ambulatory heart rate monitors and clinical electrocardiographic (ECG) devices are capable of measuring the length of consecutive cardiac periods (RR intervals). The aim of the study was to assess the agreement between the Polar 810s heart rate monitor (Polar) and the Reynolds digital ambulatory ECG using Pathfinder software version 8.4 (Reynolds v8.4) during cycle ergometry. For this purpose, eight subjects completed incremental cycling exercise that began at 60 W and increased by 30 W each 2-minute period until volitional fatigue. Simultaneous recording of the ECG (Reynolds Pathfinder), RR interval (Polar), and respiratory parameters (Metamax 3B) were undertaken at rest and throughout the exercise period. No significant differences were found in RR intervals measured by Polar and Reynolds v8.4 at any relative intensity. Polar and Reynolds v8.4 displayed strong linear relationships at all relative intensities (r2=0.927 to 0.998). Bland and Altman analyses between Polar and Reynolds v8.4 consistently demonstrated minimal bias in absolute RR interval (<0.10 ms) and the limits of agreement for group differences in RR interval and heart rate were less than +/- 10 ms and +/- 2 beats.min (-1) for all relative intensities, respectively. Power spectral analysis provided similar results for both systems in all bandwidths studied during rest and low intensity exercise. However, significant differences and large relative limits of agreement (>100 % of mean of paired means) were identified in UF at intensities > 40 % VO2max, HF at intensities > 60 % VO2max and LF during exercise at 80-100 % VO2max. These findings demonstrate that RR intervals and heart rate measurements obtained using Polar and Reynolds v8.4 are in good agreement. However, caution should be exercised when interpreting spectral analysis of RR interval data derived from different acquisition systems during physical activity.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Holter Monitor: 24-Hour Monitoring
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Dysrhythmias V: Evaluating Dysrhythmias