Related Experiment Video
Updated: Aug 20, 2026

Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Latex-coated polymeric monolithic ion-exchange stationary phases. 2. Micro-ion chromatography
Philip Zakaria1, Joseph P Hutchinson, Nebojsa Avdalovic
1Australian Centre for Research on Separation Science, School of Chemistry, University of Tasmania, Private Bag 75, Hobart, Tasmania 7001, Australia.
Abstract:
Latex-coated monolithic polymeric stationary phases are used for micro-ion chromatography (mu-IC) of inorganic anions. Monolithic columns were prepared by the in situ polymerization of butyl methacrylate, ethylene dimethacrylate, and 2-acrylamido-2-methyl-1-propanesulfonic acid within fused-silica capillaries of varying internal diameters. Introduction of ion-exchange sites was achieved by coating the anionic polymeric monolith with either Dionex AS10 or Dionex AS18 quaternary ammonium functionalized latex particles to give total ion-exchange capacities in the range 9-24 nequiv for a 30-cm column. The resultant mu-IC columns were used for the separation of anionic analytes using chloride or acetate as the eluent-competing ion and direct UV spectrophotometric detection at 195 nm or using hydroxide as the eluent-competing ion and suppressed or nonsuppressed contactless conductivity detection. Separation efficiencies of 13,000 plates/m were observed (for iodate), and separation efficiency was maintained for large increases in flow rate (up to 42 microL/min, corresponding to a linear flow velocity of 18.5 mm/s), enabling highly reproducible, rapid separations to be achieved (seven analyte anions in less than 2 min). Use of a hollow fiber micromembrane suppressor enabled effective suppression of hydroxide eluents over the range 0.5-5.0 mM, thereby permitting suppressed conductivity detection to be performed. However, the relatively large size of the suppressor resulted in reduced separation efficiencies (e.g., 5400 plates/m for iodate). Detection limits obtained with suppressed conductivity detection were in the range 0.4-1.2 microM.
More Related Videos
10:27Preparation of Highly Porous Coordination Polymer Coatings on Macroporous Polymer Monoliths for Enhanced Enrichment of Phosphopeptides
Published on: July 14, 2015
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
Related Concept Videos
Ion-Exchange Chromatography
Ion Exchange
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: