Related Experiment Video
Updated: Aug 20, 2026

Confocal Time Lapse Imaging as an Efficient Method for the Cytocompatibility Evaluation of Dental Composites
Published on: November 9, 2014
Is JPEG compression of videomicroscopic images compatible with telediagnosis? Comparison between diagnostic
Stefania Seidenari1, Giovanni Pellacani, Elena Righi
1Department of Dermatology, University of Modena and Reggio Emilia, Modena, Italy. seidenar@unimo.it
Abstract:
Early melanoma diagnosis is an important goal for dermatologists. Polarized light systems are increasingly employed for dermatoscopic diagnosis of melanocytic lesions. For the purpose of teledermoscopy, whose importance is increasingly growing for consultation and teaching purposes, it is of utmost importance to establish whether, after compression, polarized light images maintain their informativeness. The aim of our study was to check the effects of compression on melanocytic lesion images acquired by means of a digital videomicroscope on the identification of morphological details of the image and on diagnostic accuracy. A total of 170 50-fold-magnified pigmented skin lesion images, acquired in Tagged Image File Format (TIFF) by a digital videomicroscope, were compressed using Joint Photographic Experts Group (JPEG) algorithms (compression factor 30). Two experts in videomicroscopy evaluated both original and compressed images twice by describing single lesion features and expressing a diagnosis. Reproducibility in the assessment of dermoscopic parameters and observer performance were studied by kappa statistics and Receiver Operating Characteristic (ROC) analysis. Both intra- and interobserver reproducibility in the assessment of morphological details were higher when TIFF images were considered, indicating a better image quality. Nonetheless, there was no significant difference in the diagnostic accuracy between uncompressed images and compressed ones, although the intraobserver reproducibility in the diagnostic judgement was higher for uncompressed images. Despite loss in image details, factor 30 compressed videomicroscopic images enable a good diagnostic accuracy.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Three-Dimensional Microscopy in Microbiology
