Volumetric intensity dependence on the formation of molecular and atomic ions within a high intensity laser focus

Lynne Robson1, Kenneth W D Ledingham, Paul McKenna

  • 1Department of Physics, University of Strathclyde, Glasgow, Scotland, United Kingdom. l.robson@phys.strath.ac.uk

Related Concept Videos

Atomic Spectroscopy: Effects of Temperature01:27

Atomic Spectroscopy: Effects of Temperature

Atomization, converting samples into gas-phase atoms and ions, is essential for atomic spectroscopy. The flame temperature required for atomization affects the efficiency of the atomic spectroscopic methods by increasing the atomization efficiency and the relative population of the excited and ground states.
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Intensity Of Electromagnetic Waves01:22

Intensity Of Electromagnetic Waves

The energy transport per unit area per unit time, or the Poynting vector, gives the energy flux of an electromagnetic wave at any specific time. For a plane electromagnetic wave with E0 and B0 as the peak electric and magnetic fields and traveling along the x-axis, the time-varying energy flux can be given by the following equation:
Mass Spectrum: Interpretation01:24

Mass Spectrum: Interpretation

An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Sound Intensity00:58

Sound Intensity

The loudness of a sound source is related to how energetically the source is vibrating, consequently making the molecules of the propagation medium vibrate. To measure the loudness of a source, the physical quantity of interest is the intensity. This is defined as the energy emitted per unit of time per unit of area perpendicular to the sound wave's propagation direction. Since the total energy is greater if the source vibrates for a longer duration and over a larger area, dividing the emitted...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...