Related Experiment Video
Updated: Aug 20, 2026

A Modular Microfluidic Technology for Systematic Studies of Colloidal Semiconductor Nanocrystals
Published on: May 10, 2018
On-line monitoring for control of a pilot-scale sequencing batch reactor using a submersible UV/VIS spectrometer
G Langergraber1, J K Gupta, A Pressl
1Institute for Sanitary Engineering and Water Pollution Control, University of Natural Resources and Applied Life Sciences, Vienna, Muthgasse 18, A-1190 Vienna, Austria. guenter.langergraber@boku.ac.at
Abstract:
A submersible UV/VIS spectrometer was used to monitor a pilot-scale sequencing batch reactor (SBR). The instrument utilises the whole UV/VIS range between 200 and 750 nm. With just one single instrument nitrate, organic matter and suspended solids can be measured simultaneously. The spectrometer is installed directly in the reactor, measures in real-time, and is equipped with an auto-cleaning system using pressured air. The paper shows the calibration results for measurements in the SBR tank, time series for typical SBR cycles, and proposes possible ways for optimisation of the operation by using these measurements.
Related Concept Videos
UV–Vis Spectrometers
Bioreactor Controls-I
Bioreactor Design and Operational System
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview