Related Experiment Video
Updated: Aug 20, 2026

Accurate and Simple Evaluation of Vascular Anastomoses in Monochorionic Placenta using Colored Dye
Published on: September 5, 2011
Assessment of umbilical cord coiling during the routine fetal sonographic anatomic survey in the second trimester
Mladen Predanic1, Sriram C Perni, Stephen T Chasen
1Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Weill Medical College of Cornell University, 525 E 68th St, Suite M-704, New York, NY 10021, USA. mlp2001@med.cornell.edu
Objective:
The purpose of this study was to evaluate the sonographic accuracy to determine the umbilical coiling index (UCI) during the routine fetal anatomic survey in the second trimester.
Methods:
In 300 consecutive women with singleton pregnancies and absence of gross fetal anomalies who had a routine second-trimester fetal anatomic survey, a distance between 2 pairs of coils was measured from the longitudinal images of the umbilical cord, and the antenatal UCI (aUCI) was calculated. The aUCI was compared with true UCI results obtained after birth.
Results:
Two hundred thirty-six patients had adequate sonographic umbilical cord images, and all required demographic, antenatal, and labor data collection to meet the inclusion criteria. A statistically significant correlation between aUCI and true UCI was found (P < .0001; r = 0.643). The mean aUCI was 0.402 (80% confidence interval, 0.382), and the true UCI at birth was 0.203 (80% confidence interval, 0.176). The sonographic evaluation showed 12.3% and 8.9% of hypocoiled and hypercoiled cords, whereas evaluation at birth found 10.6% and 8.1% hypocoiled and hypercoiled umbilical cords, respectively. The sensitivity values of sonography to predict hypocoiling and hypercoiling at birth were 78.9% and 25.4%, respectively.
Conclusions:
A sonographic evaluation of umbilical cord coiling in the second trimester correlates with the true UCI at birth, although the sensitivity in predicting coiling patterns as hypocoiled and hypercoiled cords is less accurate. A difference between the aUCI and matched UCI at birth could be explained by a sonographic error in the sampling of different umbilical cord segments with discordant coiling patterns or the possibility of a dynamically evolving UCI with advancing gestational age.
Related Concept Videos
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection.
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Imaging Studies II: Ultrasonography

