Related Experiment Video
Updated: Aug 20, 2026

Semi-Targeted Ultra-High-Performance Chromatography Coupled to Mass Spectrometry Analysis of Phenolic Metabolites in Plasma of Elderly Adults
Published on: April 22, 2022
Clophen A60 composition and content of CBs, CNs, CDFs, and CDDs after 2D-HPLC, HRGC/LRMS, and HRGC/HRMS separation
S Taniyasu1, J Falandysz, A Swietojanśka
1National Institute of Advanced Industrial Science and Technology (AIST), EMTECH, Tsukuba, Ibaraki, Japan.
Abstract:
Chlorobiphenyl (CB) and by-side chlorodibenzofuran (CDF), chlorodibenzo-p-dioxin (CDD), and chloronaphthalene (CN) homologue group and congener composition, and concentrations have been examined in technical CBs mixture Clophen A60. 101 peaks representing 116 CB congeners were quantified in Clophen A60, and most contributing were CBs nos. 138, 153,134/144/149, and 180 with 15.4, 12.3,8.2, and 6.5%, respectively. Di-, tri-, tetra-, penta-, hexa-, hepta-, and octa-CBs constituted, respectively, 0.03, 0.03, 0.32, 9.9, 52.7, and 4.9% of chlorobiphenyls content of the Clophen A60, while mono-, nona-, and decaCB were not quantified. Tetra- to octaCDDs were absent in Clophen A60 at concentration above the method limit of quantification of <0.01 microg/g, while the total CDFs and CNs were found at 12 and 42 microg/g, respectively. Tetra-, penta-, hexa-, and hepta-CDF with 27, 46, 19, and 7% contribution, respectively, dominated in homologue group profile of CDFs, while octa-CDF was absent in Clophen A60. In compositional profile of CDF congeners the most abundant were 1,2,4,7,8-PeCDF, 2,3,4,7,8-PeCDF, and 1,2,3,4,7,8-HxCDF and each had >5% contribution. Amongst the CN homologue groups the profile in descending order followed by hepta-, hexa-, octa-, and penta-CNs with 56, 26, 16, and 2%, respectively. In compositional profile of CNs the most abundant were the congeners such as 1,2,3,4,5,6,7-HpCN (no. 73), 1,2,3,4,6,7-/1,2,3,5,6,7-HxCN (nos. 66/67), and 1,2,3,4,5,6,7,8-OcCN (no. 75) with 55, 21, and 16%, respectively. In terms of dioxin-like toxicity of Clophen A60 the contribution from planar non-ortho and mono-ortho CBs, CDFs, and CNs was 5280, 594.5, and 33.1 ng TCDD TEQ/g, respectively, and the total TEQ of planar analogues was 5908 ng/g.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
10:17High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Related Concept Videos
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)
High-Performance Liquid Chromatography: Instrumentation