Determination of cocaine and benzoylecgonine by direct injection of human urine into a column-switching liquid chromatography system with diode-array detection
Related Experiment Video
Updated: Aug 20, 2026

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
M R Brunetto1, Y Delgado Cayama, L Gutiérrez García
1IVAIQUIM (Venezuelan Andean Institute for Chemical Research), Faculty of Science, Los Andes University, P.O. Box 3 Ipostel La Hechicera, Mérida 5101-A, Venezuela. brunetto@ula.ve
Abstract:
A method for the determination of cocaine (COC) and benzoylecgonine (BZE) in human urine using a column-switching liquid chromatography system is reported. A homemade precolumn (20 mm x 4.6 mm i.d.) dry-packed with Alltech ODS-C18 (35-750 microm) was employed as an extraction precolumn in order to extract and concentrate the COC and BZE from the human urine sample. The analytes were continuously transferred to the analytical column (Spherisorb-C8, 250 mm x 4.6 mm i.d.; dp = 5 microm) by means of the switching arrangement in the backflush mode. Detection was carried out at 235 nm in a UV-diode array detector. The validation of the method revealed analytes quantitative recoveries (96-102%) at three concentrations in the range from 0.25 to 4.00 and from 0.5 to 12.0 microg/mL for COC and BZE, respectively. These values demonstrate the excellent extraction efficiency of the precolumn. The detection limits for COC and BZE at a signal-to-noise ratio of 3 were 0.08 and 0.15 microg/mL when a sample volume of 50 microL was injected. The overlap of sample preparation, analysis and recondition of the precolumn increases the sample throughput to four samples per hour. The proposed method has been applied to the determination of COC and BZE in human urine samples from 73 suspecting drug addicts. Urine concentrations of 1.0-118.10 microg of BZE/mL and 0.1-41.0 microg of COC/mL were found.
More Related Videos
13:35A Convenient Method for Extraction and Analysis with High-Pressure Liquid Chromatography of Catecholamine Neurotransmitters and Their Metabolites
Published on: March 1, 2018
06:25Post Column Derivatization Using Reaction Flow High Performance Liquid Chromatography Columns
Published on: April 26, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Gas Chromatography: Types of Detectors-II