Voltammetric study of danazol and its determination in capsules and spiked biological fluids

M Al-Omar1, A Al-Majed, M Sultan

  • 1Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia.

Related Concept Videos

Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
Drug Concentrations: Measurements01:23

Drug Concentrations: Measurements

Drug concentration is the quantity of a drug present in a biological sample. Measuring drug amounts in biological samples allows the clinician to understand how a drug is absorbed, distributed, metabolized, and excreted. Samples can be obtained through invasive or non-invasive methods. Invasive techniques involve surgical or parenteral interventions to gather blood, cerebrospinal fluid, or tissue biopsy. Conversely, non-invasive approaches provide samples like urine, feces, and saliva.
Plasma —...
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations01:15

Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations

Gentamicin, an aminoglycoside antibiotic, is commonly administered via intermittent intravenous infusion to treat severe infections. An intermittent one-hour infusion of gentamicin, administered at eight-hour intervals, allows for precise control of plasma drug concentrations, minimizing toxicity while ensuring therapeutic efficacy. Pharmacokinetic principles govern the dynamics of plasma concentrations and can be mathematically described using specific equations.The plasma drug concentration...