Related Experiment Video
Updated: Aug 19, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
[Comparison of four digital and one conventional radiographic image systems for the chest in a patient study with
U Redlich1, C Hoeschen, O Effenberger
1Klinik für Diagnostische Radiologie der Otto-von-Guericke-Universität Magdeburg.
Purpose:
Using a patient study to prove the clinical relevance of a comparison of five different radiographic systems for the chest conducted with an anthropomorphic chest phantom. Depending on the results, it was tested whether the performance of a modern digital system with a transparent imaging plate can be improved by changing the post-processing of the image.
Method:
Chest radiographs of patients were taken with a CsI/aSi-flat panel detector (FDR), transparent imaging plate (tDLR), selenium drum detector (DSR), conventional storage phosphor plate (DLR) and asymmetrical screen-film-system (aFFS), and compared using image criteria scoring (ICS) and visual grading analysis (VGA) for anatomical structures (modified criterions of the EUR 16 260 EN guidelines). After optimizing the post processing, the images of the tDLR-system were evaluated once more in a phantom ROC study and patient VGA study.
Results:
The flat panel detector-system proved to meet best the anatomical image quality criteria, followed by DSR, tDLR, aFFS and DLR. The modified post processing of the tDLR-images resulted in a significantly better detection of simulated pathological lung-structures, but improved the perceptibility of anatomical structures only slightly.
Conclusions:
The results of the patient VGA study and the phantom ROC study are similar and considered valid. The new digital imaging systems with flat panel detector and transparent imaging plate provide the best image quality of the tested radiographic devices for chest imaging, assuming that all system components are attuned and optimized for the type of structure to be detected. Image processing is of primary importance for system optimization.
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System IV: CMRI