Surface characterization of salmeterol xinafoate powders by inverse gas chromatography at finite coverage
Henry H Y Tong1, Boris Y Shekunov, Peter York
1School of Health Sciences, Macao Polytechnic Institute, Macao, People's Republic of China.
Abstract:
In our previous studies, surface analysis by inverse gas chromatography (IGC) at infinite dilution (zero coverage) was performed on four salmeterol xinafoate (SX) powdered samples, viz, two supercritical CO2-processed Form I (SX-I) and Form II (SX-II) polymorphs, a commercial granulated SX (GSX) raw material and its micronized product (MSX). Both GSX and MSX are also of the same Form I polymorph. To further probe the differences in surface properties between the samples, the present study has extended the IGC analysis to the finite concentration range of selected energy probes. The adsorption isotherms of the SX samples were constructed using (nonpolar) octane, (polar acidic) chloroform, and (polar basic) tetrahydrofuran as liquid probes. Type II adsorption isotherms with weak knees were observed with each probe for all SX Form I samples. The extents of probe adsorption by the samples at various relative pressures follow the rank order: SX-II > GSX approximately MSX > SX-I, indicating that the SX-I has fewer high-energy adsorption sites than GSX and MSX. Type III isotherms were observed for SX-II with the two polar probes, indicative of weak adsorbate-adsorbent interactions. The additional information generated shows that IGC analysis at finite coverage is a valuable complementary tool to that at infinite dilution.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Atomic Absorption Spectroscopy: Atomization Methods
