Related Experiment Video
Updated: Aug 11, 2026

Monitoring Plant Hormones During Stress Responses
Published on: June 15, 2009
Comparison of two field sampling procedures (En Core and field methanol extraction) for volatile organic compounds
Ann M Vega1, Vicki A Lancaster, Michael H Roulier
1U.S. Environmental Protection Agency, National Risk Management Research Laboratory, Land Remediation and Pollution Control Division, 26 West Martin Luther King Drive, Cincinnati, Ohio 45268, USA. vega.ann@epa.gov
Abstract:
In-situ Lasagna technology was recently evaluated at a contaminated site at Offutt Air Force Base. The site was contaminated with low levels (<30 mg/kg) of volatile organic compounds (VOCs). Originally, researchers planned to use field methanol extraction for both pre- and post-treatment sampling to evaluate the effectiveness of the technology on contaminant reduction. Precharacterization sampling, however, indicated that concentrations of some contaminants of concern were much lower than expected. Because use of methanol increases the detection limit, it was probable that post-treatment concentrations of these target contaminants would be nondetectable if methanol extraction was used. Project management, therefore, decided to use En Core samplers in addition to field methanol extraction during the pretreatment sampling event. The En Core sampling approach, while yielding a lower detection limit, uses discreet samples along the length of a core, whereas the methanol extraction approach samples the entire length of the core. The concern was that discreet samples may bias results if any "hot spots" were present. The two field sampling procedures, En Core and field methanol extraction, were performed side-by-side during the pretreatment phase of the technology evaluation in order to determine if the concern was valid for this site. Results were compared for four contaminants of concern: trichloroethylene, vinyl chloride, cis-1,2-dichloroethene, and trans-1,2-dichloroethene. The two procedures produced similar results with respect to both the concentration means and the variances, and no bias was evident. This finding supports project management's decision to use only En Core samplers post-treatment due to low concentrations of target contaminants.
More Related Videos
09:38Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures
Published on: January 7, 2019
09:19Capturing Actively Produced Microbial Volatile Organic Compounds from Human-Associated Samples with Vacuum-Assisted Sorbent Extraction
Published on: June 1, 2022
Related Concept Videos
Solvents
A...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Volatilization
Sampling Methods: Sample Types
Solid samples include a variety of substances, such as sediments from water bodies, soil, metals, and biological tissues. Two standard methods for extracting sediments from water bodies are grab sampling and piston coring. Grab sampling involves using a device to collect a discrete sediment sample from the bottom of a water body with minimal disturbance. Grab samples do not always represent the entire area due to...
Sample Preparation for Analysis: Advanced Techniques
Acid digestion with strong acids is commonly used to dissolve inorganic materials that are insoluble (do not dissolve) in water. This method can be useful for...
Chromatographic Methods: Terminology