Related Experiment Video
Updated: Aug 19, 2026

A Multicenter MRI Protocol for the Evaluation and Quantification of Deep Vein Thrombosis
Published on: June 2, 2015
Comparison of different iodine concentrations for multidetector row computed tomography angiography of segmental
Joern J W Sandstede1, Christine Kaupert, Anne Roth
1Department of Radiology, University of Wuerzburg, Germany. sandstede@web.de
Abstract:
The aims of this study were (1) to assess the diagnostic performance of multidetector row computed tomography angiography (CTA) on imaging of renal artery branches and (2) to investigate the effect of different iodine concentrations at constant total iodine load and either constant injection rates or constant iodine administration rates. A number of 120 consecutive patients (71+/-6 years of age) underwent CTA of renal arteries (collimation 4 x 1 mm) using the nonionic contrast medium iopromide, and were divided into six equal groups: 1: 150 ml, 240 mg/ml at 4 ml/s; 2: 120 ml, 300 mg/ml at 4 ml/s; 3: 97.3 ml, 370 mg/ml at 4 ml/s; 4: 150 ml, 240 mg/ml at 5 ml/s; 5: 120 ml, 300 mg/ml, 60 ml at 6 ml/s, 60 ml at 3 ml/s; 6: 97.3 ml, 370 mg/ml at 3.3 ml/s. The image quality of the main renal arteries (n=240) and their first-order to fourth-order branches was scored as 0 for no visualization, 1 for only visualization, and 2 for diagnostic. All main renal arteries were diagnostic. First-order branches had score 2 in 38/40, 40/40, 37/40, 38/40, 39/40, and 40/40 patients for groups 1-6, respectively (p=0.34). Second-order branches were imaged best in group 2 (p<0.002)). Third-order branches had score 2 in only 1/40, 5/40, 1/40, 2/40, 0/40, and 2/40 renal arteries. Fourth-order branches were not imaged diagnostically. At a constant total iodine load, the main renal arteries and their first-order branches achieved diagnostic image quality at all iodine concentrations in four-channel multidetector row CTA for the protocols tested. Second-order renal artery branches were imaged best at 120 ml contrast medium with an iodine concentration of 300 mg/ml at 4 ml/s.
More Related Videos
06:02Anatomical Reconstructions of the Human Cardiac Venous System using Contrast-computed Tomography of Perfusion-fixed Specimens
Published on: April 18, 2013
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies VII: Vascular Imaging
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT