Background:
Intramedullary screws frequently are used for fixation of Jones fractures of the fifth metarsal. While the ability of intramedullary screw fixation in fifth metatarsals to resist bending and tensile forces is well known, the ability to withstand torsion has not been studied. This paper compares the torsional stiffness of Jones fractures treated with 6.5-mm short- threaded intramedullary screws to those treated with 5.0-mm cannulated short-threaded intramedullary screws.
Methods:
Nine fresh-frozen, matched pairs of cadaver fifth metatarsals had an acute Jones fracture simulated with an osteotomy. They were stabilized with intramedullary screws and then loaded to failure.
Results:
The torsional stiffness of the metatarsals fixed with the 6.5-mm did not differ significantly from that using 5.0-mm screws. However, to achieve stability, the 5.0-mm screw had to be long enough to reach the metatarsal head and neck. This tended to straighten the normally curved fifth metatarsal bone and caused lateral gapping at the fracture site.
Conclusion:
Both 5.0-mm or 6.5-mm screws provide equal torsional rigidity, but 5.0-mm screws may need to be longer, which could potentially straighten the fifth metatarsal shaft in patients who have a curved fifth metatarsal.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Normal Strain under Axial Loading