Related Experiment Video
Updated: Aug 19, 2026

Watershed Planning within a Quantitative Scenario Analysis Framework
Published on: July 24, 2016
Setting site-specific water-quality standards by using tissue residue criteria and bioaccumulation data. Part 1.
John E Toll1, Lucinda M Tear, David K DeForest
1Toll Environmental, Seattle, Washington 98105, USA. john@tollenvromental.com
Abstract:
We have developed a method for determining site-specific water-quality standards (SSWQSs) for substances regulated based on tissue residues. The method uses a multisite regression model to solve for the conditional prior probability density function (PDF) on water concentration, given that tissue concentration equals a tissue residue threshold. The method then uses site-specific water and tissue concentration data to update the probabilities on a Monte Carlo sample of the prior PDF by using Bayesian Monte Carlo analysis. The resultant posterior PDF identifies the water concentration that, if met at the site, would provide a desired level of confidence of meeting the tissue residue threshold contingent on model assumptions. This allows for derivation of a SSWQS. The method is fully reproducible, statistically rigorous, and easily implemented. A useful property of the method is that the model is sensitive to the amount of site-specific data available, that is, a more conservative or protective number (water concentration) is derived when the data set is small or the variance is large. Likewise, as the site water concentration increases above the water-quality standard, more site-specific information is needed to demonstrate a safe concentration at the site. A companion paper demonstrates the method by using selenium as an example.