Related Experiment Video
Updated: Aug 19, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Use of solid-phase microextraction followed by on-column silylation for determining chlorinated bisphenol A in human
M del Olmo1, A Zafra, B Suárez
1Department of Analytical Chemistry, University of Granada, E-18071 Granada, Spain. mdolmo@ugr.es
Abstract:
In this study, a solid-phase microextraction (SPME) method based on poly(acrylate)-coated fibres has been developed for detection and quantification of chlorinated bisphenol A in human plasma due to the need for an assessment of human exposure to them. After desorption of the analytes for 7 min at 300 degrees C, they were directly derivatized in the GC injector port by injection of 2 microL of diluted bis(trimethylsilyl)trifluoroacetamide (BSTFA). The formation of trimethylsilylate derivatives improves the selectivity, sensitivity and performance of the chromatographic properties obtained when the analytes are directly separated. Quantification was carried out using single-ion monitoring (SIM). The respective chloroderivative molecular ions appear at 406, 440, 474 and 508 m/z; whereas the base peaks corresponding to a loss of a methyl group in all cases appear at 391, 425, 459 and 493 m/z for mono-, di-, tri- and tetrabisphenol A, respectively. Deuterated bisphenol A (BPA-d16) was used as an internal standard. The method was applied to the determination of Cl-BPA, Cl2-BPA, Cl3-BPA and Cl4-BPA at very low concentration levels in plasma. Recovery efficiencies were close to 100% in all cases.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
High-Performance Liquid Chromatography: Elution Process
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...