Magnetic resonance perfusion tracks 133Xe cerebral blood flow changes after carotid stenting
Nerissa U Ko1, Achal S Achrol, Alastair J Martin
1Department of Neurology, University of California, San Francisco, USA.
Background And Purpose:
To compare magnetic resonance (MR) perfusion to gold-standard cerebral blood flow (CBF) determined by intra-arterial (133)Xe washout method.
Methods:
Eight patients with high-grade carotid stenoses underwent bolus-tracking MR perfusion and intra-arterial (133)Xe washout before and after carotid stenting. MR perfusion was compared with 133Xe-CBF values using Pearson linear correlation analysis.
Results:
We observed a mean 37+/-38% increase in 133Xe-CBF and a mean 19+/-27% increase in relative CBF (rCBF) by MR perfusion immediately after stent placement. Relative (percent) changes in MR-rCBF showed a close and linear correlation to those seen in 133Xe-CBF (r=0.91; R2=0.84; P=0.002). There was a trend for MR perfusion to underestimate change in CBF at higher relative changes in flow.
Conclusions:
Bolus-tracking MR perfusion correlates with 133Xe-CBF in estimating postprocedural increases in blood flow but may underestimate the magnitude of the change with higher relative changes.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI