Related Experiment Video
Updated: Jul 21, 2026

Nine-Grid Area Division Method: A New Ideal Bone Puncture Region for Percutaneous Vertebroplasty in Lumbar Spine
Published on: August 9, 2024
Effect of cement volume and placement on mechanical-property restoration resulting from vertebroplasty
Sean Molloy1, Lee H Riley, Stephen M Belkoff
1Orthopaedic Instrumentation Laboratory, Department of Orthopaedic Surgery, the Johns Hopkins University/Johns Hopkins Bayview Medical Center, 4940 Eastern Avenue A672, Baltimore, MD 21224-2780, USA.
Background And Purpose:
Concern exists that vertebral bodies augmented with cement placed laterally may be at risk of collapse on the nonaugmented side. The purpose of the current study was to determine if placing the cement laterally rather than centrally resulted in risk of collapse on the nonaugmented side.
Methods:
Vertebral bodies (L2-L5) were harvested from eight osteoporotic female cadaver spines. Simulated vertebral-body compression fractures were created and stabilized by injecting 3.5 or 7.0 mL of cement centrally or laterally. Vertebral bodies were recrushed to measure their augmented strength and stiffness. Anterior, posterior, left, and right lateral heights were measured initially, after augmentation, and after recompression.
Results:
Lateral and central 3.5-mL injections of cement restored strength, whereas 7.0-mL injections significantly increased strength compared with initial values. The stiffness of vertebral bodies receiving central 3.5-mL injections was significantly less than it was initially, although the stiffness of bodies receiving 3.5-mL laterally was not significantly different from initial values. Initial and posttreatment stiffness values did not significantly differ in vertebral bodies receiving 7.0-mL, lateral or central injections. Vertebral heights did not significantly differ between the augmented and the final compression states in any location. Height loss between central and lateral injections did not differ significantly.
Conclusion:
Vertebral bodies in which cement is placed laterally do not appear to be at risk for collapse on the unaugmented side.
More Related Videos
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
07:06Surgical Technique for the Implantation of a Biomimetic Artificial Intervertebral Disc in a Goat Animal Model
Published on: October 10, 2025
Related Concept Videos
Setting Time of Cement
Soundness of Cement
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...
Total Voids in Concrete
Plasticizers
Plasticizers function by using surface-active agents to create repulsive electrostatic forces between cement particles. This dispersion enhances the concrete's...