What is the adequate sampling interval of the ECG signal for heart rate variability analysis in the time domain?
Laszlo Hejjel1, Elizabeth Roth
1Heart Institute, Medical Faculty, University of Pecs, Pecs, Hungary. lhejjel@freemail.hu
Abstract:
Heart rate variability (HRV) analysis is considered a simple method for investigating neurocardiac regulation. However, measures of HRV may be corrupted by technical artifacts. In order to investigate the consequences of digitization errors on the time domain parameters, HRV measures from model tachograms resampled at different rates were compared. Two 375-element tachograms from human ECG tracings were shifted to a mean of 800 ms and stretched to standard deviations (SD) of 5-120 ms in 5 ms steps. All were resampled at 1-10 ms in 1 ms steps, 10 times repetitively at each interval. The mean, SD, relative accuracy error (RAE) and relative precision error (RPE) were calculated from the mean RR-interval, SD (SDNN), root mean square of successive RR-differences (RMSSD) and the percentage of consecutive RR-interval differences greater than 50 ms (pNN50). The RAE and RPE of the mean heart rate were below 0.1%. In the series with 5 ms SD, the SDNN-RAE exceeded 30% at 10 ms SI, its RPE was lower than 2% all through. Resampling the 15 ms SD tachogram at 1, 2, 4, or 10 ms resulted in RMSSD-RAE of 0.7%, 2.5%, 7.8% and 45.1%, respectively, while its RPE remained below 5%. The pNN50 shows poor accuracy and precision. An ECG sampling interval of 1 ms is recommended for HRV analysis without interpolation in order to get accurate time domain measures even in seriously reduced-variability samples. However, a lower sampling rate may be satisfactory in cases where higher variability is expected.
Related Concept Videos
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias III: Characteristics of Dysrhythmias