Related Experiment Video
Updated: Jul 27, 2026

Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Speciation of volatile aromatic and chlorinated hydrocarbons in an urban atmosphere using TCT-GC/MS
O Baroja1, E Rodríguez, Z Gomez de Balugera
1Department of Analytical Chemistry, Faculty of Pharmacy University of the Basque Country, Vitoria-Gasteiz, Spain.
Abstract:
Several aromatic and chlorinated volatile hydrocarbons (VOCs) were measured in Vitoria-Gasteiz City (Spain) throughout the years 1999 and 2002 in order to find out the concentration of these pollutants in urban air. These VOCs were retained in Tenax TA, subsequently desorpted by using a thermal desorption cold trap injector (TCT), and thereafter analyzed by gas chromatography/mass spectrometry (GC/MS). This analytical methodology permits the determination of 42 VOCs at very low concentrations, although only 32 of them were found in the urban air of the city (ranging from 205.51 to 0.01 microg m(-3)), with high reproducibility (%RSD lower than 10%). Twenty-four-hour samples were taken each sampling day to ascertain their total daily concentration, and rigorous quality controls were carried out to check the representativeness of sampling. Results of this exhaustive study show that toluene (T), xylenes (X), ethylbenzene (E), and benzene (B) were, respectively, the most abundant of these VOCs in the urban area during that period. The total concentration of BTEX represented, on average, more than 72.6% of the VOC total concentration, with the highest concentrations being reached in autumn, except for benzene and derived compounds (in winter). Benzene was the minority BTEX pollutant, its yearly mean concentration being less than the maximum established by the European Directive 2000/69/CE (5 microg m(-3)).
More Related Videos
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Mass Spectrometry: Cycloalkane Fragmentation
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Mass Spectrometry: Aromatic Compound Fragmentation
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...