The haptic kymograph: a diagnostic tele-haptic device for sensation of vital signs
1Virtual Reality Laboratory, 809 Furnas Hall, Department of Mechanical and Aerospace Engineering, The State University of New York at Buffalo, Buffalo, NY 14260, USA. {ykim5,kesh}@eng.buffalo.edu
Abstract:
The kymograph is device for measuring and presenting pressure-based signals, such as human heart beat and artery volume pressure. The Haptic Kymograph is a haptically-enhanced tele-medicine system which is used to acquire human vital signs and then to transform these signs into sensible, scalable and ubiquitous media so that a user can easily comprehend subtle and ambiguous signals in a remote place. In an experiment setup a patient's artery pressure pulse was captured at 200 Hz of sampling rate, transmitted via TCP/IP network, and replicated in a remote place using a PHANToM haptic device coupled with a real-time visual interface. In this paper we report our recent progresses in developing a low-cost input system, network interfaces and haptic replication of the human artery volume pulse signal.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring