The Abbott Architect c8000: analytical performance and productivity characteristics of a new analyzer applied to
Daniela Pauli1, Michael Seyfarth, Leif Dibbelt
1Central Laboratory, Department of Clinical Chemistry, UK S-H, Campus Luebeck, Luebeck, Germany.
Abstract:
Applying basic potentiometric and photometric assays, we evaluated the fully automated random access chemistry analyzer Architect c8000, a new member of the Abbott Architect system family, with respect to both its analytical and operational performance and compared it to an established high-throughput chemistry platform, the Abbott Aeroset. Our results demonstrate that intra- and inter-assay imprecision, inaccuracy, lower limit of detection and linear range of the c8000 generally meet actual requirements of laboratory diagnosis; there were only rare exceptions, e.g. assays for plasma lipase or urine uric acid which apparently need to be improved by additional rinsing of reagent pipettors. Even with plasma exhibiting CK activities as high as 40.000 U/l, sample carryover by the c8000 could not be detected. Comparison of methods run on the c8000 and the Aeroset revealed correlation coefficients of 0.98-1.00; if identical chemistries were applied on both analyzers, slopes of regression lines approached unity. With typical laboratory workloads including 10-20% STAT samples and up to 10% samples with high analyte concentrations demanding dilutional reruns, steady-state throughput numbers of 700 to 800 tests per hour were obtained with the c8000. The system generally responded to STAT orders within 2 minutes yielding analytical STAT order completion times of 5 to 15 minutes depending on the type and number of assays requested per sample. Due to its extended test and sample processing capabilities and highly comfortable software, the c8000 may meet the varying needs of clinical laboratories rather well.
More Related Videos
08:12Characterization, Quantification and Compound-specific Isotopic Analysis of Pyrogenic Carbon Using Benzene Polycarboxylic Acids (BPCA)
Published on: May 16, 2016
10:22Split Point Analysis and Uncertainty Quantification of Thermal-Optical Organic/Elemental Carbon Measurements
Published on: September 7, 2019
Related Concept Videos
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Lab