Patient specific optimization of the relation between CT-hounsfield units and proton stopping power with proton
Uwe Schneider1, Peter Pemler, Jürgen Besserer
1Department of Radiation Oncology and Nuclear Medicine, City Hospital Triemli, 8063 Zürich, Switzerland. uwe.schneider@psi.ch
Abstract:
The purpose of this work is to show the feasibility of using in vivo proton radiography of a radiotherapy patient for the patient individual optimization of the calibration from CT-Hounsfield units to relative proton stopping power. Water equivalent tissue (WET) calibrated proton radiographs of a dog patient treated for a nasal tumor were used as baseline in comparison with integrated proton stopping power through the calibrated CT of the dog. In an optimization procedure starting with a stoichiometric calibration curve, the calibration was modified randomly. The result of this iteration is an optimized calibration curve which was used to recalculate the dose distribution of the patient. One result of this experiment was that the mean value of the deviations between WET calculations based on the stoichiometric calibration curve and the measurements was shifted systematically away from zero. The calibration produced by the optimization procedure reduced this shift to around 0.4 mm. Another result was that the precision of the calibration, reflected as the standard deviation of the normally distributed deviations between WET calculation and measurement, could be reduced from 7.9 to 6.7 mm with the optimized calibration. The dose distributions based on the two calibration curves showed major deviations at the distal end of the target volume.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT