An easily integrative and efficient micromixer and its application to the spectroscopic detection of glucose-catalyst
1Department of Biomedical Engineering, Dankook University, San 29, Anseo-Dong, Cheonan, Chungnam 330-714, S. Korea. dbiomed@dankook.ac.kr
Abstract:
The focus of this paper is on the fabrication of a PDMS-based passive efficient micromixer to be easily integrated into the other on-chip microfluidic system. The mixing is achieved by "strong stretching and folding," which employs a three-dimensional microchannel structure. By the simultaneously vertical and transversal dispersion of fluids, strong advection is developed. Owing to this powerful mixing performance (more than 70% of the mixing is accomplished within 2.3 mm over a wide range of Reynold number (Re)), the smaller integrative mixer can be realized. The feasibility and the potential usefulness of an integrative micromixer were evaluated by incorporating two mixers into the microchannel for the spectroscopic detection of a glucose-catalyst reaction. The results demonstrate a promising performance for diverse applications in the assay or synthesis of biological or chemical materials.