Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
[Ultrasound stethoscope in the rapid assessment of left ventricular systolic function and valvular
Piotr Szymański1, Magdalena Lipczyńska, Anna Klisiewicz
1Pracownia Echokardiografii Kliniki Wad Wrodzonych Serca, Instytutu Kardiologii w Warszawie. p.szymanski@ikard.waw.pl
Background:
Recent technological advances enabled miniaturization of echocardiographic machines and construction of portable "ultrasound stethoscopes", which enable rapid two-dimensional and color-Doppler imaging and supplement clinical examination of the heart. We present the results of systematic assessment of these devices in comparison with standard echocardiographic machines.
Methods:
We prospectively examined with both ultrasound stethoscopes and standard echocardiographic machines 60 patients referred to our laboratory for routine echocardiographic examination. Image quality (score: 1 to 4; best to worst), accuracy in qualitative evaluation of valvular regurgitation and left ventricular function (ejection fraction) were directly compared. Color Doppler assessment of valvular regurgitation was graded on a standard four point scale. A two or more point difference was considered major. Ejection fraction was estimated (the ultrasound stethoscope is not equipped with appropriate software).
Results:
Image quality was significantly worse in the case of ultrasound stethoscope (2.6 vs 2.1; p<0.0001). Major differences in the assessment of regurgitant jets were present in 3 cases (5%) (1 mitral and 2 tricuspid). The degree of agreement was good in the case of mitral and pulmonary regurgitation (kappa=0.61 and 0.74 respectively), very good in the case of aortic regurgitation (kappa=0.80) and moderate in the case of tricuspid regurgitation (kappa=0.48). The differences in the assessment of aortic and mitral regurgitant jets correlated with the image quality (p<0.05). A Bland-Altman graph comparing the results of ejection fraction assessment revealed good agreement between methods.
Conclusions:
Results of the systematic evaluation of the use of ultrasound stethoscopes in the rapid evaluation of left ventricular systolic function and valvular regurgitation. Although image quality achieved with the hand-held stethoscope was worse, nevertheless it was adequate for the purpose of performing rapid limited assessment of cardiac and valvular function.
More Related Videos
03:40Point-of-Care Ultrasound for Peripheral Veno-Arterial Extracorporeal Membrane Oxygenation Without Left Ventricular Venting
Published on: January 17, 2025
10:33Assessment of Right Ventricular Structure and Function in Mouse Model of Pulmonary Artery Constriction by Transthoracic Echocardiography
Published on: February 3, 2014
Related Concept Videos
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...