Neonates do not need to be handled for radiographs.

Dawn Slade1, Sara Harrison, Susan Morris

  • 1Department of Child Health, Llandough Hospital, Penarth, Cardiff CF64 4XX, UK. dawnslade@doctors.org.uk

Pediatric Radiology
|February 24, 2005
PubMed
Summary

The under-tray radiography technique for neonates offers comparable image quality to the standard method. This approach minimizes handling, reducing risks like hypoxia and bradycardia in sick infants.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Outcomes of Surgical Site Infection Following Cranial Surgery From a UK Tertiary Center.

Open forum infectious diseases·2026
Same author

The relationship between umbilical arterial pH, newborn heart rate and ventilation at birth - a prospective observational study.

Resuscitation·2026
Same author

Content Validity and Psychometric Evaluation of the Idiopathic Hypersomnia Severity Scale (IHSS) in Adults with Idiopathic Hypersomnia.

Nature and science of sleep·2026
Same author

Embedding Multiperspective Reflections in Co-Producing a Training Intervention for Care Home Staff: Understanding Group Members' Journeys and Impacts.

Health expectations : an international journal of public participation in health care and health policy·2026
Same author

Budesonide and Surfactant Therapy Versus Surfactant Alone on Incidence of Lung Disease in Preterm Infants (BEST Lung): Study Protocol for a Systematic Review and Individual Participant Data Meta-Analysis With Nested Prospective Meta-Analysis.

Acta paediatrica (Oslo, Norway : 1992)·2026
Same author

Closing the Gap to Interventions for Tuberous Sclerosis Complex-Associated Neuropsychiatric Disorders (TAND): Protocol for a Longitudinal Study of TAND Severity, Predictors, and Caregiver Well-Being (TANDem-2).

JMIR research protocols·2026

Area of Science:

  • Neonatal care
  • Pediatric radiology
  • Medical imaging techniques

Background:

  • Handling sick neonates during procedures like radiography can cause adverse events such as hypoxia and bradycardia.
  • Minimizing infant handling is crucial for improving outcomes in neonatal care.
  • Modern incubators offer an under-tray option for radiographic cassette placement, potentially reducing the need for direct infant handling.

Purpose of the Study:

  • To compare the quality of neonatal chest radiographs obtained via the standard direct contact method versus the under-tray technique.
  • To evaluate if the under-tray method compromises diagnostic image quality.

Main Methods:

  • A retrospective analysis of 70 neonatal chest radiographs (25 standard, 45 under-tray) was conducted.
  • Two consultant pediatric radiologists independently assessed image quality based on exposure, blurring, rotation, cut-off, and side markers.

Related Experiment Videos

  • A subjective quality score was also assigned by each radiologist.
  • Main Results:

    • The under-tray method showed a statistically significant advantage in exposure quality for one radiologist and in cut-off for the other.
    • No significant differences in image quality were found for blurring, rotation, or side markers between the two methods.
    • Infant weight and radiation exposure levels were comparable between both techniques.

    Conclusions:

    • The under-tray radiography technique yields neonatal chest films of at least equivalent quality to the standard direct contact method.
    • Given the risks associated with handling neonates, the under-tray method is recommended to cease the standard technique.
    • Implementing the under-tray method can enhance patient safety by reducing handling-related complications.