Related Experiment Video
Updated: Jul 15, 2026

Inducing Apical Periodontitis in Mice
Published on: August 6, 2019
Effects of endodontic irrigation solutions on mineral content of root canal dentin using ICP-AES technique
1Department of Endodontics, Selcuk University Faculty of Dentistry, Konya, Turkey. Hale29tr@yahoo.com
Abstract:
The aim of this in vitro study was to evaluate mineral content of root canal dentin after treatment with several endodontic irrigation solutions. Sixty mandibular anterior teeth extracted for periodontal reasons used. The crowns of the teeth were removed at the cemento-enamel junction. Pulp tissues were removed and the teeth were randomly divided into six groups including 10 teeth each. Root canals were enlarged with gates-glidden burs (# 1, 2, and 3). The groups were treated as follows: group 1, 0.2% chlorhexidine gluconate for 15 min; group 2, 3% H2O2 for 15 min; group 3, 17% EDTA for 15 min; group 4, 5.25% NaOCl for 15 min; group 5, 2.5% NaOCl for 15 min; and group 6, distilled water (control). Dentin chips were obtained using gates-glidden burs (# 4, 5, and 6). The levels of five elements calcium, phosphorus, magnesium, potassium, and sulfur in each specimens were analyzed using ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrometry) technique. Changes in the levels of the chemical elements were recorded. The results were then statistically analyzed by one-way ANOVA and Tukey tests. There was a significant decrease in the calcium and phosphorus levels after treatment with all irrigation solutions except for 5.25% NaOCl when compared with the control group (p < 0.05). The K, Mg, and S level changes were not statistically significant (p > 0.05). It has been concluded that endodontic irrigation solutions have an effect on mineral contents of root dentin.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Emission Spectroscopy: Lab