A clinical water-coated antenna applicator for MR-controlled deep-body hyperthermia: a comparison of calculated and
Jacek Nadobny1, Waldemar Wlodarczyk, Lothar Westhoff
1Charité Universitätsmedizin Berlin, Campus Virchow Klinikum, Klinik für Strahlenheilkunde, Augustenburger Platz 1, 13353 Berlin, Germany. jacek.nadobny@charite.de
Abstract:
A magnetic resonance (MR)-compatible three-dimensional (3-D) hyperthermia applicator was developed and evaluated in the magnetic resonance (MR) tomograph Siemens MAGNETOM Symphony 1.5 T. Radiating elements of this applicator are 12 so-called water coated antenna (WACOA) modules, which are designed as specially shaped and adjustable dipole structures in hermetically closed cassettes that are filled by deionized water. The WACOA modules are arranged in the applicator frame in two transversal antenna subarrays, six antennas per subarray. As a standard load for the applicator an inhomogeneous phantom was fabricated. Details of applicator's realization are presented and a 3-D comparison of calculated and measured temperature data sets is made. A fair agreement is achieved that demonstrates the numerically supported applicator's ability of phase-defined 3-D pattern steering. Further refinement of numerical models and measuring methods is necessary. The applicator's design and the E-field calculations were performed using the finite-difference time-domain (FDTD) method. The calculation and optimization of temperature patterns was obtained using the finite element method (FEM). For MR temperature measurements the proton resonance frequency (PRF) method was used.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...