Related Experiment Video
Updated: Aug 19, 2026

Thermal Scanning Conductometry (TSC) as a General Method for Studying and Controlling the Phase Behavior of Conductive Physical Gels
Published on: January 23, 2018
Study on resolution capacity and secondary mechanisms of three different TSK gels for organic SEC
Juan Figueruelo1, Rosa García-Lopera, Manuel Falo
1Department de Química Física Institut de Ciència dels Materials 50 46100 Burjassot, Spain.
Abstract:
A comparative study on the elution behavior in size-exclusion chromatography (SEC) of three polymeric TSK gel packings, named H, H(HR), and H(XL) types, is performed. The deviations of the universal calibration (u.c.) curves of seven solvent-polymer systems show evidence that the existence of secondary effects accompanying the main SEC mechanism. These secondary mechanisms are a consequence of the binary enthalpic interactions between the different components of the chromatographic system, such as polymer-solvent, polymer-gel and solvent-gel. However, in the present case, the observed deviations from a unique u.c. curve can mainly be attributed to adsorption of polymeric solutes (analytes) onto the residual moieties of the gel surfaces, (i.e., to polymer-gel interactions). These enthalpic interactions can be quantitated by the values of the distribution coefficient, Kp, which follows the order: Kp (gel H(XL)) > Kp (gel H(HR)) > Kp (gel H). Moreover, the specific resolution of the three types of packings is also estimated, and its comparison yields that Rsp (gel H(HR)) > Rsp (gel H(XL)) > Rsp (gel H), in good agreement with their increasing particle size and decreasing crosslinking degrees. Finally, the errors and inaccuracies committed on the estimation of the sample average molar masses from their respective calibration curves serves the assessment that the packing with lesser secondary mechanisms is the H-type.
Related Concept Videos
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Racemic Mixtures and the Resolution of Enantiomers
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...