Effect of age on left ventricular systolic function in humans: a study of systolic isovolumic acceleration rate
1Section of Cardiology, Department of Medicine, Baylor College of Medicine, and Debakey Heart Center, The Methodist Hospital, Houston, TX 77030-2717, USA.
Abstract:
The aim of this study was to examine the effect of age on left ventricular (LV) systolic function in normal healthy adults. Eighty consecutive subjects without cardiovascular disease underwent standard and tissue Doppler (TD) echocardiographic imaging. LV systolic function was assessed by load-dependent indices as ejection fraction (EF) and myocardial systolic velocities by TD as well as by the load-independent index, systolic isovolumic acceleration rate (IVA). None of the echocardiographic measurements of systolic function declined with age (mean IVA for the group, 286 +/- 123 cm s(-2); IVA vs. age, r = 0.21, P = 0.1). Likewise, LV end diastolic dimension, wall thickness, mass and left atrial maximum volume were not significantly related to age. On the other hand, as previously reported, echocardiographic indices of diastolic function showed a significant decline with age (P < 0.05). When the group was stratified by gender, isovolumic velocity and acceleration were higher in men than women, but the differences were not significant (P = 0.12 and 0.37, respectively). No significant relation was observed between age and measurements of LV systolic function by regression analysis in women (P > 0.1). However, in men, a positive correlation was noted between average IVA and age (r = 0.63, P = 0.007). In conclusion, age is not associated with a change in cardiac structure and LV systolic function, but is accompanied by a decline in echocardiographic indices of diastolic function. With respect to gender, age does not appear to influence LV systolic function in women, but is associated with an increase in IVA and septal systolic ejection in men.
Related Concept Videos
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Heart Failure II: Pathophysiology
Regulation of Stroke Volume
Preload refers to the degree of stretch on the heart before it contracts. It's analogous to the stretching of a rubber band; the more it's stretched, the more forcefully it snaps back. This concept is encapsulated in the Frank-Starling law of the...