Related Experiment Video
Updated: Aug 19, 2026

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
[The study on fabrication of dental restoration using PMMA-ZrO2 composites via CAD/CAM]
Shi-bao Li1, Zhong-yi Wang, Zhao-hui Chen
1Key Lab for Materials, College of Aerospace and Materials Engineering, National University of Defense Technology, Changsha 410073, China.
Objective:
To obtain dental restorations by machining PMMA-ZrO2 organic-inorganic composites with the dental CAD/CAM system.
Methods:
Partially sintered Zirconia compacts (PSZC) were prepared via isostatic pressing and partially sintering, with Zirconia nanopowder as raw materials. PMMA-Zirconia organic-inorganic composites were prepared by vacuum infiltrating the prepolymerized MMA into the PSZC, followed by in-situ polymerization. The mechanical properties and machinability of composites were studied. The composites were machined on the dental CAD/CAM system to obtain dental restoration.
Results:
At 71.44% TD of PSZC, the composite had a 3-point bending strength of (202.56 +/- 3.09) MPa, fracture toughness of (4.30 +/- 0.16) MPa.m(1/2), elasticity modulus of (58.71 +/- 1.98) GPa, and Vickers hardness of (3.82 +/- 0.34) GPa, respectively. A premolar crown was fabricated by CAD/CAM system in 16 mins, and was verisimilitude, without any cracks.
Conclusions:
The composite at 71.44% TD of PSZC has good mechanical properties and dental restorations can be manufactured by PMMA-Zirconia composites via dental CAD/CAM system.